Polymer Modified Bitumen Tank SBM-30

Polymer Modified Bitumen Tank

Polymer Modified Bitumen Tank. GloveCore offers SBM-30 modified bitumen tank to businesses involved in road construction and repairs, structure waterproofing as well as soft roof construction. SBM-30 is an insulated vessel for storage of polymer bitumen bitumen.

The use of polymer-modified bitumen for production of asphalt mix allows the road top to quickly recover from stresses generated by heavy traffic. Bitumen and polymer combinations have found many uses in construction of road layers. As shown by experience, using this material ensures high durability of roads even in harsh conditions.

Such modified bitumen can also be used for:

  • filling of deformation seams on bridges;
  • filling of cracks in asphalt layers;
  • sealing of plots for garbage collection etc.

SBM-30 components

SBM modified bitumen collection tank consists of:

  • vane agitator with drive;
  • heat exchanger to maintain the required bitumen temperature;
  • emergency overflow pipeline;
  • valves for bitumen input and output;
  • valves for heating medium input and output;
  • sight hatch and service gangways;
  • control cabinet.

The control cabinet is used to start the agitator drive and to monitor such parameters as temperature and bitumen level. If bitumen level exceeds a certain level, a special sensor engages alarm.

SBM-30 modified bitumen collection tank specifications

No

Parameter

Value

1

Total tank volume, cubic meters, not less than

32

2

Usable volume, cubic meters, not less than

30

3

Power voltage, V

380

4

Power frequency, Hz

50

5

Power consumption, kW

30

6

Agitator rotation speed, rpm

400

7

Heat exchanger surface area, square meters

22

8

Heating medium volume, liters

250

9

Heat insulation thickness, mm

200

10

Dimensions for transportation, mm, not more than:

-length

12000

-width

2400

-height

2550

11

Dimensions in operation, mm, max:

-length

2850

-width

2800

-height

12000

12

Weight, kg, max

8500

13

Weight loaded, kg, max

40000
14

Calculated load on each support of foundation slab, tons

10

15

Drop of bitumen temperature depending on tank fullness at ambient temperature 5oС, oС in 24 hours

1-2

SBM-30 modified bitumen storage tank advantages:

  • reduced heat loss due to inverted cone bottom and insulation;
  • shape of the top of the tank prevents rain water accumulation;
  • bitumen level monitoring;
  • bitumen temperature monitoring;
  • sensor indications on the control cabinet;
  • emergency overflow pipeline prevents hot bitumen spills;
  • competitive price.

GlobeCore specialists are ready to develop and manufacture custom equpment for bitumen facilities.

обновлено: February 14, 2017 автором: dannik